Technical data
To help you with your calculations and dimensioning, we've tried to bring together here all the relevant information on the tubes and beams in our range. Please do not hesitate to contact us for further details, in particular on the chemical and mechanical properties of steels, etc. You can consult by product family or download all the technical specifications of our tubes and beams using the .pdf files below.
Date of last update: Apr, 22 2025
Technical data of sections UPE
UPE Channels with parallel flanges
Range UPE
Designation | G kg/m |
Dimensions | I cm2 |
Section properties | Equivalent 1 | Equivalent 2 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
h mm |
b mm |
tw mm |
tf mm |
r mm |
Strong axis | Weak axis | |||||||||||
Iy cm4 |
Wely cm³ |
Wply cm³ |
Iy cm |
Iz cm4 |
Welz cm³ |
Wplz cm³ |
iz cm |
||||||||||
UPE 80 | 7.9 | 80.0 | 50.0 | 4.0 | 7.0 | 10.0 | 10.10 | 107 | 26.8 | 31.2 | 3.26 | 25 | 8.0 | 14 | 1.59 | ||
UPE 100 | 9.8 | 100.0 | 55.0 | 4.5 | 7.5 | 10.0 | 12.50 | 207 | 41.4 | 48.0 | 4.07 | 38 | 10.6 | 19 | 1.75 | ||
UPE 120 | 12.1 | 120.0 | 60.0 | 5.0 | 8.0 | 12.0 | 15.40 | 364 | 60.6 | 70.3 | 4.86 | 55 | 13.8 | 25 | 1.90 | ||
UPE 140 | 14.4 | 140.0 | 65.0 | 5.0 | 9.0 | 12.0 | 18.40 | 600 | 85.6 | 98.8 | 5.71 | 79 | 18.2 | 33 | 2.07 | ||
UPE 160 | 17.0 | 160.0 | 70.0 | 5.5 | 9.5 | 12.0 | 21.70 | 911 | 113.9 | 131.6 | 6.48 | 107 | 22.6 | 41 | 2.22 | ||
UPE 180 | 19.7 | 180.0 | 75.0 | 5.5 | 10.5 | 12.0 | 25.10 | 1,353 | 150.4 | 173.0 | 7.34 | 144 | 28.6 | 52 | 2.39 | ||
UPE 200 | 22.8 | 200.0 | 80.0 | 6.0 | 11.0 | 13.0 | 29.00 | 1,909 | 190.9 | 220.1 | 8.11 | 187 | 34.4 | 63 | 2.54 | ||
UPE 220 | 26.6 | 220.0 | 85.0 | 6.5 | 12.0 | 13.0 | 33.90 | 2,682 | 243.9 | 281.5 | 8.90 | 246 | 42.5 | 78 | 2.70 | ||
UPE 240 | 30.2 | 240.0 | 90.0 | 7.0 | 12.5 | 15.0 | 38.50 | 3,599 | 299.9 | 346.9 | 9.67 | 311 | 50.1 | 92 | 2.84 | ||
UPE 270 | 35.2 | 270.0 | 95.0 | 7.5 | 13.5 | 15.0 | 44.80 | 5,255 | 389.2 | 451.1 | 10.83 | 401 | 60.7 | 112 | 2.99 |
Designation | G kg/m |
Dimensions | I cm2 |
Section properties | Equivalent 1 | Equivalent 2 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
h mm |
b mm |
tw mm |
tf mm |
r mm |
Strong axis | Weak axis | |||||||||||
Iy cm4 |
Wely cm³ |
Wply cm³ |
Iy cm |
Iz cm4 |
Welz cm³ |
Wplz cm³ |
iz cm |
||||||||||
UPE 300 | 44.4 | 300.0 | 100.0 | 9.5 | 15.0 | 15.0 | 56.60 | 7,823 | 521.5 | 613.4 | 11.76 | 538 | 75.6 | 137 | 3.08 | ||
UPE 330 | 53.2 | 330.0 | 105.0 | 11.0 | 16.0 | 18.0 | 67.80 | 11,010 | 667.1 | 791.9 | 12.74 | 682 | 89.7 | 156 | 3.17 | ||
UPE 360 | 61.2 | 360.0 | 110.0 | 12.0 | 17.0 | 18.0 | 77.90 | 14,830 | 823.6 | 982.3 | 13.79 | 844 | 105.1 | 178 | 3.29 | ||
UPE 400 | 72.1 | 400.0 | 115.0 | 13.5 | 18.0 | 18.0 | 91.90 | 20,980 | 1,049.0 | 1,263.0 | 15.11 | 1,045 | 122.6 | 191 | 3.37 |